From a kit of parts to a finished building, in four steps.
Every building starts as one kit of parts: columns, rim beams, floor and ceiling joists, connectors and braces. The parts are fabricated from steel coil, pre-punched for bolts and bundled flat for shipment. A single 40-foot container carries the complete kit for up to 12 modules.

A design study, then every component detailed, fabricated, quality-controlled and packed for delivery.
Take delivery of a flat load and bolt it together. No structural fabrication capability is required.
The module is the volumetric unit, bolted together from that kit. No part of it is welded on site. Two workers with a lift can assemble a frame in 45 minutes, as shown in True Volumetric’s timed trials. Corridor frames are a flat-pack variant that ties the modules on either side of a hallway together.


A frame goes together in this order:
Supply the frames, engineered and fabricated, flat-packed as a kit or assembled.
Assemble the frame, then fit it out with drywall, services and finishes in your own plant.
Modules and corridor frames group into the standard arrangement: a double-loaded corridor with modules facing each other and a corridor frame set between them. The corridor frames tie the two rows into one diaphragm, and the whole group lands on a single foundation. Daggers are already in place, so the frames bolt together with no site welding.


Because each frame carries its own braces, no other structure is needed. The same kit of parts makes short, tall or wide buildings, whether double-loaded, single-loaded or point-block. The frame has been assessed to ten storeys.

Engineer and supply a system of frames and connections that stacks into many building configurations.
Decide the massing. Your engineer of record sizes the columns and braces to suit the arrangement.
METALOQ Documentation v1.0, pages 5–10. Select a page to enlarge it.
Every building starts as a kit of parts: columns, rim beams, joists, connectors, and braces. Each is fabricated from coil and bundled for shipment. Nearly any shape the design team specifies can be configured from this kit of parts.
Components bolt together to make the two basic assemblies needed to create buildings: room modules of any shippable dimension and corridor frames that span between the room modules. Examples are shown in §0.5.
For more information follow the links below:
• Column options
• Rim beam design
• Floor & ceiling joists
• Crossbraces
• Dogbone connector
• Dagger connector
• Corridor connectors
• Clamp connections
• Taper-lock
• The standard frame
• Modes of variability
• Stairs
• Seismic strategies
• Frame catalogue
• Transport & handling
Modules and corridor frames group to create the standard arrangement: a double-loaded corridor with volumetric modules facing each other and a flat-pack corridor frame hung between them. The same arrangement adapts to turn a 90° corner.
Many sizes and shapes of building can be created with the same system, including tall or short buildings, single- or double-loaded corridors, a straight bar, an L, a full courtyard, and many combinations in between, all landing on a common foundation.
For more information follow the links below:
• Corridor diaphragm
• Cores & brace frames
• Zero-clearance stacking
• Set sequence
• The 90° corner in plan
• Product Lines (Ch 8)
• Reference massing
• Corner plans compared
• Turning the corner
• Core assemblies
• Foundations (Ch 5)
Every module is made from one kit of parts: columns, beams, floor and ceiling joists, and connection hardware. The details and limitations of each component are given in Components (Ch 3). The components are fabricated from coil, pre- punched for bolts, and stacked into a tight bundle for shipment, so what arrives at a plant is a flat load of components that bolt together quickly to make a finished frame. One module’s entire kit, sorted by component, is shown on the facing page. Every frame in this manual is built from that same kit.
WHAT WE DO Study The first step is a design study confirming that METALOQ meets the project requirements for size, variants, fire rating and cost. Design The project architect and engineer then detail the building, with input and coordination from METALOQ advisors. Delivery Once the design is complete, our design team details every component for fabrication and produces the cut and assembly files. The frames are quality-controlled, then packed in a shipping container for delivery. WHAT YOU DO You take delivery of a flat load and bolt it together. The components are fabricated to tolerance, so no structural fabrication capability is required.
PACKED FOR SHIPMENT
For quality control, a sample of frames is pre-assembled to prove the fit, then knocked down and packed to ship. A single 40-foot container carries the complete kit for up to 12 modules.
For more on packing and shipping, see Packing & Shipping (§7.3 Logistics).
Left — a layout of all the components for a single module. Module sizes and component lists vary.
The module is the volumetric unit, bolted together from the same kit shown in §0.1. It is shown exploded (top) and assembled (bottom) on the facing page. No part of the module is welded on site.
Modules can be fabricated in a range of lengths, widths, and heights. A factory runs more efficiently with the fewest possible variants within a given project, so most projects use a small set of standard sizes and reduce the one-off sizes as much as possible. The variations are shown in §0.5 on Variability.
A corridor frame is a flat-pack variant that ties the modules on either side together and ensures overall diaphragm action. It occupies the hallway between paired module rows and is the principal in-plane stiffness element of a grouped METALOQ building. It is bolted together (shown below).
WHAT WE DO We supply the frames: engineered, fabricated, and delivered flat-packed as a kit, or assembled. WHAT YOU DO Two workers with a lift can assemble a frame in 45 minutes as demonstrated by True Volumetric’s timed trials. You then fit it out with drywall, services, and finishes in your own plant.
1. Rim floor beam and columns 2. Rim ceiling beams → preliminary square 3. Floor and ceiling joists 4. Braces → final square 5. Floor: services under floor, and floor deck 6. Stud framing: wood or LGS studs and framing 7. Fit-out: services, drywall, finishing
CORRIDOR FRAME
DESIGN RULE Floor vs. rooftop corridor frame
Corridor frames at floor levels match the full depth of the module’s rim floor beams, and can be up to 3 module bays wide. Rooftop corridor frames are shallower, to match the rim ceiling beam, and resist only roof diaphragm reactions (see §4.2).
§0.3 · THE STACK
Eight modules, the corridor frames, and the foundation are shown exploded and assembled. Volumetric modules and corridor frames are shipped to site to be assembled. They are stacked together to make a double-loaded building structure, with modules on either side of the corridor. The corridor frame for the next level goes on top, which creates a waterproof datum for the level above.
The frame shown on this sheet is a 2×2×2 stack: 2 wide × 2 high × 2 deep (double-loaded). The corridor frames tie the two rows of modules into one diaphragm, and the whole group lands on a single foundation. Every load path described in Assemblies (Ch 4) is present in this arrangement. The drawings show every possible brace location. Commonly only one brace per module side is needed, so the designer can choose where to leave bracing out for doors, windows, or wider rooms. The engineer of record confirms the final brace layout.
WHAT WE DO We supply the module frames and the corridor frames that make the arrangement, along with the hardware needed to connect the frames together. WHAT YOU DO Your engineering team verifies overall performance, then you fit out and stack the modules on either side of the corridor, and set the corridor frame on top. The daggers are already in place, so there is no site welding. You can simply bolt the frames together.
Since individual frames include their own braces, no other structure is needed. To stack higher and wider, increase the column thickness and the brace capacity. The same kit of parts is used for short, tall, or wide buildings, whether double-loaded, single-loaded, or point-block.
The corridors are where the horizontal and vertical service connections are made. Services run along the ceiling and in chase walls to connect directly to the pre- wired units. Power, alarm wiring, heating and cooling pipes, and sprinklers also run along the corridor ceiling and into the ceiling space of each module. Water, sanitary, storm, and gas risers fit into the corridor chase walls (see §6 MEP Services) and connect on site to the services pre-installed in each module. The roof is either a separate module set last, or built in the plant on top of the uppermost module.
The frame has been assessed to ten storeys. See §2.6 The Ten-Storey Building, with the taller cases in §2.7 Tall Buildings.
WHAT WE DO We engineer and supply a system of frames and connections that stacks into many building configurations. WHAT YOU DO You decide the overall massing, and your engineer of record sizes the columns and braces to suit your arrangement.
The completed section shown in this illustration is composed of 32 modules and includes an elevator and stairs. It is available as a predesigned 4×4×2 stack for your evaluation. You can complete the modules with a variety of exterior cladding and interior finishes, as a proof-of-concept structure. Contact True Volumetric Corporation (Canada and USA) or METALOQ International for more information.
For more information see also §8.1 Off-the-shelf Reference Massing.
§0.5 · VARIABILITY — FRAME ASSORTMENT
The METALOQ system is highly adaptable, from a common set of components. The connections and members are made to order, with standard frame sizes that suit most mid-rise designs. Industrial tailoring, made to measure.
This section is an orientation to the METALOQ system. It does not replace project-specific architecture or engineering, and nothing here should be relied on to design a building. Every project needs licensed professionals and the approval of the authorities having jurisdiction. Illustrations are not to scale.