Where the building meets the ground, and how services connect.
Because modules stack with zero clearance, any error at the foundation carries up the full height of the building. An accurately built foundation gives a dimensionally stable stack. METALOQ recommends scanning the foundation before the pour and surveying the anchors after it.

Six foundation conditions are supported:
All mechanical, electrical, plumbing and fire-protection services inside a module are installed at the factory and travel with it. Each service is capped where modules meet and reconnected on site, most effectively on the corridor side of the unit.

The frame accommodates services in four standard ways:
A patent-pending METALOQ method connects risers between modules without the usual post-set work. Connectors carried in the frame engage as the next module lands, and the system is installed and tested in the factory.
METALOQ Documentation v1.0, pages 47–49. Select a page to enlarge it.
CHAPTER
This chapter explores the various foundation types that are compatible with the METALOQ system. An accurately built foundation ensures a dimensionally stable stack. Because modules stack with zero clearance, any error at the foundation carries up the full height of the building.
METALOQ supports six foundation interface conditions, shown in the details on sheet M1.03 of the Common detail library in the previous section.
1. DET 01 — Slab on grade — ground slab, engineered by others; weep holes in the base trim. 2. DET 02 — Foundation wall — cast wall, grout levelled gusset plate with optional COR-0003 cast-in-pocket. 3. DET 03 — METALOQ foundation frame — an optional frame with dagger connections for the modules above and anchor rods into the concrete. 4. DET 04 — Steel pile — grade beam poured over screw piles; anchor plate set after the pour. 5. DET 05 — Steel podium — site-built steel podium; beam size and dagger slip as specified by the structural engineer. 6. DET 06 — Concrete basement — basement wall; sill-block seal tied into the membrane layers.
The foundation hardware is based on the dagger system. It locates the ground-floor module laterally and transfers axial loads to the foundation below.
A foundation-level corner connector (§3.10, COR-0003) may also connect the frame directly to the concrete. This connector is a steel fabricated box cast into a pocket in the foundation wall, and the module corner seats on it and bolts into it.
The foundation connection points must be set within tight tolerances for a METALOQ frame to seat correctly. The limits are set out below.
DESIGN RULE Stack accuracy propagates from the foundation
Foundation hardware must be set to ±3 mm of the METALOQ grid at the ground-floor datum. METALOQ recommends a LiDAR scan of the foundation before the pour and a survey of the anchor rods after the pour to confirm the as- built condition.
Plumbing access hatch: 14″ × full height, fire-rated.
Riser infill threaded up through the floor opening
Clamp-patch closes the joint once the infill is in place
Hole for riser: fire block
Option to fill chase with insulation for fire block
CHAPTER
All MEP and fire-protection services inside a module are installed at the factory and travel with the finished module. Each service is capped at the mateline and reconnected on site.
Connections are most effectively made on the corridor side of the unit, at one of two locations: in the ceiling space at the corridor wall, or in a riser chase within the corridor wall at floor level. All typical services can be accommodated by this method, as set out below.
SERVICE CONNECTION LOCATION Electrical power Junction box or unit sub-panel Main feeders along the corridor ceiling, or in a riser. Fire alarm and detection Alarm, strobe, smoke/carbon monoxide Wired on site in preinstalled conduit to each device. Gas (cooking) Kitchen range Corridor ceiling space or riser. Heating and cooling piping HVAC units (FCU or ERV) Ceiling or riser, supplied from central boilers or heat pumps. Fresh air intake Exterior wall of the module Bulkhead inside unit to the HVAC equipment. Sprinkler Sprinkler heads in unit ceiling Main runs along the corridor and branches into each unit. Domestic hot and cold water Plumbing fixtures and sinks Corridor ceiling space, or a vertical riser in the corridor wall. Sanitary drain and vent Risers in the corridor wall Risers run down to grade and up to the roof. Fire hose cabinet supply Fire hose cabinet Corridor side of the corridor wall, in a fire-rated enclosure. Make-up air Fresh air to corridors and common space Vertical shaft within the module or on the corridor side. Garbage chute Vertical shaft within the module Requires sound attenuation.
The METALOQ frame accommodates services and connections in four standard ways.
1. Ceiling space The fire-rated ceiling is tight to the underside of the ceiling frame, which leaves room above a dropped ceiling for services to pass from the corridor ceiling into the unit. Each penetration of the corridor wall is fire-stopped to the listing of the rated assembly. 2. Chase wall The corridor and the unit meet at the rim beam. The chase is built inside the module, just inside the rim beam, which allows services to be pre-connected inside the module. 3. Floor and ceiling joists The joists are manufactured with openings designed for floor plumbing and ceiling wiring. Deeper joists can be specified where a sanitary line needs a longer slope; even so, plumbing is best kept close to the corridor chase. 4. Wall studs Wiring runs in the stud walls with a 1″ clear gap at the top of perimeter walls for access to the ceiling cavity. 5. No penetrations of the frame With these four routes, no service penetrates a column or a rim beam.
Fig. 6.1 — FIG.112: the service connection bay at the module interface
This section describes the patent-pending METALOQ method for connecting risers between modules.
A vertical connection on a sanitary pipe is conventionally made by stopping the riser 2′ above the floor of the upper module and 2′ below the ceiling of the module beneath. On site, the plumber feeds a length of pipe through pre-drilled openings and makes a clamped connection at the top and the bottom. Domestic water requires a similar, though simpler, connection.
The Autonomous MEP Connection eliminates post-set connections altogether. Its patent-pending connectors carry electrical, water and sanitary couplings that engage as the module lands. This is possible only because of the zero-clearance design of the METALOQ frame. Further information is available upon request.
The METALOQ autonomous MEP system is fully installed and tested in the factory. A gasket is placed at each junction, so that when the next module lands it seals the gap. The module lands completely connected.
This section is an orientation to the METALOQ system. It does not replace project-specific architecture or engineering, and nothing here should be relied on to design a building. Every project needs licensed professionals and the approval of the authorities having jurisdiction. Illustrations are not to scale.